Xuzhou Sunwell Power Transmission Machinery Co.,Ltd.

PVG Proportional Valves

Home > Products > Sauer-Danfoss

PVG16 Proportional Valve

The PVG 16 is a new member of the PVG family of valves. The PVG portfolio now comprises PVG 16, 32, 100 and 120 –providing flow up to 240 l/min. A common feature is the modular build concept.
This enables engineers to combine stacks of flexible slice-sections across the entire PVG family, making it possible to build up a valve group that meets precise requirements. Furthermore, the compact external dimensions of the valve remain unchanged, no matter what combination is specified.
The PVG 16 is a hydraulic, loadsensing proportional valve, designed to give maximum flexibility in the design and build concept.
The PVG 16 is also designed as a load-sensing directional control valve, which helps improve application efficiency – reducing both cooling requirements and fuel expenses.
For more information, please click the link below:
PVG16 Proportional Valve
 

Maximum pressure

Port P continuous

350 bar 1)

[5075 psi]

Port P intermittent

400 bar

[5800 psi]

Port A/B continous

380 bar

[5510 psi]

Port A/B intermittent

420 bar

[6090 psi]

Port T, static/dynamic

25/40 bar

[365/580 psi]

Oil flowrate

Port P 

140/230 l/min

[37/61 US gal/min]

Port A/B 

65 l/min

[17 US gal/min]

Spooltravel 

Deadband

土 1.5 mm

[± 0.06 in]

Proportional range

土 5 mm

[± 0.2 in]

Float position

土 7.5 mm

[± 0.3 in]

Maximum internal leakage at100bar [1450 psi] 21mm2/s [102 SUS]

A/B → T without shock valve

20 cm3/min

[1.85 in3/min]

A/B → T with shock valve (system setting 30bar [435 psi])

25 cm3/min

[2.15 in3/min]

Oil temperature(inlet temperature)

Recommended temperature

30 → 60 °C

[86 →140°F]

Minimum temperature

-30 °C

[-22 °F]

Maximum temperature

90 °C

[194 °F]

Ambient temperature

 

-30 → 60 °C

[-22 →140 °F]

Oil viscosity

Operating range

12 - 75 mm2/s

[65 - 347 SUS]

Minimum viscosity

4 mm2/s

[39 SUS]

Maximum viscosity

460 mm2/s

[2128 SUS]

Filtration

Maximum contamination (ISO 4406)

23/19/16

PVM regulating range

Proportional range

13.9°

Float position

22.3°

PVM operating force

PVM + PVMD

Neutral position

2.2 ±0.2 N.m

[5.0 ± 1.8 丨bf.in]

Maximum stroke

2.8 ±0.2 N.m

[6.3 ± 1.8 丨bf.in]

PVM + PVE2)

Neutral position

2.2 ±0.2 N.m

[5.0 ± 1.8 丨bf.in]

Maximum stroke

2.8 ±0.2 N.m

[6.3 ± 1.8 丨bf.in]

PVM + PVH

Neutral position

2.7 ±0.2 N.m

[23.9 土 1.8丨bf.in]

Maximum stroke

7.1 ±0.2 N.m

[62.8 ± 1.8丨bf.in]

PVH pressure

Regulating range

5 - 15 bar

[75 - 220 psi]

Maximum pilot pressure

30 bar

[435 psi]

Maximum pressure on T-port

10 bar

[145 psi]

PVE input voltage 3)

Supply voltage UDC

11 - 32 Vdc

Regulating range

25% UDC - 75% Udc

PVE SP pin output voltage 3)

Float

0.5 Vdc

Flow to B-port

1.25 - 2.5 Vdc

Neutral

2.5 Vdc

Flow to A-port

2.5 - 3.75 Vdc

Error

5 Vdc


1) With PVSI end plate. Using PVS end plate maximum 300 bar [4351 psi].
2) PVE without voltage.
3) Voltage is measured between spool output pin and ground (GND).