Electrical Parameters | |
---|---|
Sensor type | Potentiometric |
Electrical angle of movement | ± 28° |
Total track resistance | 4 kΩ or 5 kΩ (± 20%) |
Maximum supply voltage (Vs) | 35 Vdc |
Maximum wiper current | 5 mA (non-destructive) |
Maximum power dissipation | 0.25 W at 20 °C [at 68 °F] |
Wiper circuit impedance | 200 kΩ minimum |
Output voltage | 10 to 90 % Vs |
25 to 75 % Vs | |
Resolution | Infinite |
Center tap voltage (no load) | 50 % Vs ± 2% |
Center tap angle | ± 2.5° either side of center (±1° tolerance) |
Insulation resistance | > 50 MΩ at 500 Vdc |
Connector | 7 pin AMP® series latching male |
Switch operating angle | ± 5° of center (± 1° tolerance) |
Load resistance minimum | 10 kΩ |
Load current maximum | 2 mA resistive |
Mechanical Parameters | ||
---|---|---|
Lever type | Short lever | Long lever |
Breakout force (at lever tip) | 3.1 N [0.70 lbf ] | 2.3 N [0.52 lbf ] |
Operating force (at tip, full deflection) | 5.1 N [1.15 lbf ] | 3.4 N [0.76 lbf ] |
Maximum allowable force | 50 N [11.24 lbf ] | 35 N [7.87 lbf ] |
Lever operating angle | ± 30° | |
Lever action | Self centering or end return | |
Expected life | > 5000000 cycles | |
Weight | 0.045 kg [0.099 lb] |
Environmental Parameters | |
---|---|
Operating temperature | -25°C to 70°C [-13 °F to +158°F] |
Storage temperature | -40°C to 85°C [-40°F to +185°F] |
Environmental sealing above the flange | IP 66 - BS EN 60529 |