Xuzhou Sunwell Power Transmission Machinery Co.,Ltd.

Hydrostatic Drives

Home > Products > Sauer-Danfoss

90 Series Axial Pump & Motor

Series 90 hydrostatic pumps and motors can be applied together or combined with other products in a system to transfer and control hydraulic power. They are intended for closed circuit applications.
• Series 90 – advanced technology
• Seven sizes of variable displacement pumps
• Proven reliability and performance
• Compact, lightweight
• Worldwide sales and service
• PLUS+1™ compliant controls and sensors
Series 90 variable displacement pumps are compact, high power density units. All models utilize the parallel axial piston/slipper concept in conjunction with a tiltable swashplate to vary the pump’s displacement. Reversing the angle of the swashplate reverses the flow of oil from the pump and thus reverses the direction of rotation of the motor output.
Series 90 pumps include an integral charge pump to provide system replenishing and cooling oil flow, as well as control fluid flow. They also feature a range of auxiliary mounting pads to accept auxiliary hydraulic pumps for use in complementary hydraulic systems. A complete family of control options is available to suit a variety of control systems (mechanical, hydraulic, electric).
Series 90 motors also use the parallel axial piston/slipper design in conjunction with a fixed or tiltable swashplate. They can intake/discharge fluid through either port; they are bidirectional. They also include an optional loop flushing feature that provides additional cooling and cleaning of fluid in the working loop.
For more information, please click the link below:
90 Series Axial Pump & Motor
System pressure Maximum working pressure bar [psi] 450 [6525]
Maximum pressure 480 [6960]
Maximum low loop pressure 45 [650]
Minimum low loop pressure 10 [145]
Charge pressure Minimum bar [psi] 18 [261]
Maximum 34 [493]
Control pressure Minimum (at corner power for EDC and
FNR)
bar [psi] 14 [203]
Minimum (at corner power for NFPE) 22 [319]
Maximum 40 [580]
Charge pump
inlet pressure
Rated bar (absolute) [in Hg vacuum] 0.7 [9]
Minimum (cold start) 0.2 [24]
Maximum bar [psi] 4 [58]
Case pressure Rated bar [psi] 3 [44]
Maximum 5 [73]
Lip seal external pressure Maximum bar [psi] 0.4 [5.8}